T-Frame Mount |
|
The sectorized mount allows for attachment of multiple cellular antennas at the same elevation. The rotatable sectorized mount has gates mounted off each apex or face of the tower. Each gate can be oriented by changing the position of the stiff arm brackets. Sectorized mounts can be designed for guyed or self-supporting towers of any make or model. Antenna mounting pipes and universal mounts must be ordered separately. |
|
|
|
|
|
|
|
|
|
|
Side Arm Mount |
|
Side arm mounts provide an extended 2-7/8" or 4" OD mounting pipe and are available in stock sizes of 3-foot or 6-foot. Mounts attach to any type tower leg, and are provided with holes to attach stiffarms, (ordered separately) if needed. A universal mount may be employed to attach a side arm to a tapered or larger leg. Side arm mounts can be custom designed for larger or tapered legs. Mounting hardware included. |
|
|
|
|
|
|
|
|
|
|
Dish Mount |
|
The dish mount attaches to the face of the tower and is designed to accept up to a 4-1/2" OD dish mounting pipe at any of three points. For mounting on a tower apex, EEI recommends a Universal Mount. The dish mount shown is for a guyed tower. Mounts can be designed to be bolted or clamped on any make or type of structure. Available with stiff-arm tie-back angle upon request. Mounting pipes sold separately. |
|
|
|
|
|
|
|
|
|
|
Universal Mount |
|
The universal mount is a versatile solution for the attachment of any large assembly to a guyed or self-supporting tower leg. It provides a single 4-1/2" OD x 5' pipe on a very wide range of leg sizes, and is perfect for the attachment of a large t-frame mount or a large dish. The upper attachment point is adjustable, allowing compensation for a tapered tower section of 15 degrees of vertical down-tilt control. The two sizes of the mount cover virtually every existing size of tower leg, from small round members and angle to large-scale lattice. |
|
|
|
|
|
|
|
|
|
|
Pipe Mount |
|
The pipe mount is a lighter weight version of the universal mount that fits angle and plate legs up to 4" x 4" and pipe or solid round legs from 1 1/2" diameter to 4 1/2" diameter. The pipe mount does not allow for tapered adjustment. |
|
|
|
|
|
|
|
|
|
|
Tower Diagonals |
|
Often, an existing guyed or self-supporting tower must be modified to meet design specifications for existing or proposed loading. Ehresmann Engineering can design and fabricate tower diagonal members to convert a single-laced bracing pattern to a double-laced pattern for increased tower strength, or to replace existing diagonal members with members of a larger size. |
|
|
|
|
|
|
|
|
|
|
Ice Shields |
|
Ice shields protect dishes and other mounts from falling ice. Each ice shield includes mounting assemblies for attachment to a 4-1/2" OD mounting pipe (order mounting pipe separately, if needed). |
|
|
|
|
|
|
|
|
|
|
Torque Arm Stabilizer (Sample 1) |
|
A stabilizer can be installed on a guyed tower at or near the elevation of microwave antennas, in order to minimize twist of the tower and deflection of the beam path. Stabilizers can be furnished for any make or model of guyed tower. All items are hot dip galvanized. The assembly includes all necessary mounting hardware. |
|
|
|
|
|
|
|
|
|
|
Torque Arm Stabilizer (Sample 2) |
|
A stabilizer can be installed on a guyed tower at or near the elevation of microwave antennas, in order to minimize twist of the tower and deflection of the beam path. Stabilizers can be furnished for any make or model of guyed tower. All items are hot dip galvanized. The assembly includes all necessary mounting hardware. |
|
|
|
|
|
|
|
|
|
|
Anchor Shafts |
|
The anchor shafts shown are typical for guying a small to moderate guyed tower. Anchor shafts are designed with varying head size, shaft size, shaft length, and number of holes, dependent on the size of the tower and on calculated tension requirements. Anchor shafts can be designed for any loading condition. Designs include the double configuration shown and the Caisson type anchor. |
|
|
|
|
|
|
|
|
|
|
Anchor Head Adapters |
|
Used to provide additional attachment points on an existing guy anchor, anchor head adapters allow addition of extra guys. Adapters can be made with multiple holes. Standard adapters accept up to two 3/4" turnbuckles. Plate thickness and hole sizes are determined by requirements of a specific project. The capacity of the existing anchor shafts to accept an anchor head adapter must be determined by the consumer. This service can also be provided by Ehresmann Engineering. Call for information. Adapters may be configured either at right angles, as shown or parallel to the main anchor head. |
|
|
|
|
|
|
|
|
|
|
Waveguide Ladder |
|
Waveguide ladders provide a means of supporting feedlines on a rigid platform that can be mounted to the face of any tower. Holes are provided to accommodate snap-in waveguide hangers. All items are hot-dip galvanized. All necessary harware for attaching the ladders to tower face is furnished. Snap-in hangers not included. |
|
|
|
|
|
|
|
|
|
|
T-Shape Waveguide Hangers |
|
Waveguide Hangers attach to the legs of either guyed or self-supporting towers and accept up to 24 snap-in hangers. T-hangers are attached to round legs with U-bolts for easy installation. Angle legs require custom manufacture. Specify angle size when ordering. Normal installation calls for approximate 4-foot vertical spacing. Hangers are shipped with all required mounting hardware. Snap-in hangers are not included. |
|
|
|
|
|
|
|
|
|
|
W-Shape Waveguide Hanger |
|
The W-shape hanger attaches to the tower leg for distribution of lines on either side of the tower apex. Waveguide Hangers accept up to 24 snap-in hangers. W-hangers are attached to round legs with U-bolts for easy installation. Angle legs require custom manufacture. Specify angle size when ordering. Normal installation calls for approximate 4-foot vertical spacing. Hangers are shipped with all required mounting hardware. Snap-in hangers are not included. |
|
|
|
|
|
|
|
|
|
|
Waveguide Plates |
|
Universal waveguide plates are used to attach waveguide ladders to tower members using j-bolts. Universal plates also attach climbing ladder sections to towers. Splice plates link ladder sections. |
|
|
|
|
|
|
|
|
|
|
Climbing Ladder |
|
Climbing ladders meet or exceed minimum requirements of TIA/EIA-222F. Side members are punched to accommodate 3/4" rungs, for added security. Ladders are hot-dip galvanized and include tower-specific mounting hardware. |
|
|
|
|
|
|
|
|
|
|
Step Bolts |
|
Step bolts are hot-dip galvanized and include two heavy hex nuts. |
|
|
|
|
|
|
|